Power Controller
  Syncronous Firing (Zero Cross Over)
This is also commonly known as zero cross over firing or burst firing method. In this technique, we trigger the scr at the moment sine wave crosses zero and the anode is driven positive, the power control is achieved by having the scrs on for some cycles and off for other cycles. The ratio of no. Of cycles on to no. of cycles off is varied to proportional the power delivered to the load.
 
  Advantages of Syncronous Firing :
Conventional voltmeters and ammeters can be used for instrumentation at 50% to 100% voltage range
Infinitely variable output
Elimination of rfi
More uniform power distribution
No flickers on the lighting load
Achieves near unity power factor
   
Product Specifications Instruction Manual
 
  Phase Angle Firing
In this method, thyristor is triggered in every cycle. Basically we are delaying the scr gating until some time after the voltage crosses the zero, by varying this delay (measured in electrical degrees) in turn we are controlling the conduction i.e. the on time, and as such the power output to the load is controlled.

There are certain applications which requires continuous proportional power. Even certain heating elements requires only phase angle type power controller, namely silicon carbide, super kenthal, infrared heaters and transformer coupled heaters.

In certain closed loop applications the phase angle power controller gives more flexibility and it accepts various feed back signals. With phase angle power controller, the application engineer gets the options of current limiting feature, voltage limiting feature, constant current mode, power feed back, constant kw output and even true rms power controlling.

The power control should be selected considering the line voltage variation and change in the resistance of element with respect to temperature. Another important thing is that, supply cable must be rated at rms current drawn by the element (i.e. current = power / thyristor output voltage and not power / supply voltage).

Following is the few basic configurations, which we generally use for our various industrial applications as shown in figure.
 
1 or 2 Phase, 2 Wire Connection
 
3 Phase, 3 Wire Star Connection
3 Phase, 4 Wire STAR Connection
3 Phase, 3 Wire Closed Delta Connection
3 Phase, 6 Wire Open Delta Connection
   
Product Specifications Instruction Manual
 
 Top
 
Home  |  About Mifa  |  Customised Services  |  System Solutions  |  Application  |  Contacts  |  Download Catalog  | 
Download Manuals  |  Site Map   |  Dealer Network  |  Enquiry
Toho Electronics  |  Keba  |  Eutech Instruments  |  Schneider Electric  |  Larsen & Toubro Ltd.  |  Wedgewood Analytical Inc.  |  Simex
Controllers - Toho Electronics Inc., Japan  |  Motion Controllers/Variable Speed Drives - L&T  |  Servo Motor & Drives - L&T  |  D.C. Drives - L&T  | 
Soft Starter - L&T  |  Injection Mould Controllers - Keba  |  Software & Allied Services  |  PLCs/HMI - Schneider Electric  |  Panels & Power Controllers  | 
Hot Runner  |   Analytical Instruments - Eutech Instruments  |  pH/ORD Electrode - Wedgewood Analytical Inc.  |  Data Loggers - Simex
Copyright ©2005 Mifa Systems Pvt.Ltd. All rights reserved.